6-744011-7
Used with
Usable oil
cylinder
capacity
492cm³
Single acting
[30in³]
WARNING: These pumps are operated with a non vented reservoir. If the reservoir is subjected to high
pressure, the casing may rupture, causing personal injury and/or equipment damage. NEVER attempt to
return more oil to the reservoir than it is capable of holding.
NOTE: The pumps are equipped with a clicker valve which opens as soon as the set pressure is reached.
During operation this valve clearly indicates that the working pressure of 700 bars respective 580 bars is
reached.
6

Installation

6.1 Connecting the pump

1. Insert the male coupling of the hydraulic hose into the female coupling on the pump. Tighten the cap
nut on the pump (see figure 4, 5 and 6).
Figure 3
Pressure rating
Model
number
1. stage
2. stage
700bar
523199-2
(yellow)
15bar
[10.000psi] 11,26cm³
[220psi]
580bar
523199-3
(blue)
[8286psi]
Table 1
Page 21 / 26
Oil displacement
Max.
per stroke
handle
effort
1. stage
2. stage
2,47cm³
42kg
[.687in³]
[.151in³]
[93lbs]
ECOC: EGC0 ; LOC: AI
412-18745 Rev.B
Piston
Weight
stroke
25,4mm
7,0kg
[1,00Zoll] [15,4lbs]