GENERAL PRECAUTION
Check that the voltage and frequency of the power supply
l l
match those required by the system.
Check the possibility to have the power line to the indoor
l l
unit (ELECTRIC CABLE LENGTH 3 m).
Install a double - pole switch, protected by 10 A fuses of the
l l
delayed type, upstream the electricity wall socket.
Make sure that the electrical installation is suitable to supply
l l
continuosly current necessary for the air conditioner in
EG
addition to that already used by other electric appliances
(white goods, lighting). See the max electric imput indicated
on the name plate positioned on the air conditioner.
Before connecting the air conditioner to a power sock-
l l
et, make sure that the socket is provided with an earth
connection in compliance with local codes.
INSTALLATION SITE SELECTION
INDOOR UNIT
AVOID:
Positioning the indoor unit into rooms where it could be
l l
sprinkled with water (i.e. laundries).
leakage of flammable gas or large amount of mist may be
expected humidity location.
source that may affect performance of the unit.
behind curtains or furniture that obstruct air circulation.
DO:
Choose a position which allows proper ventilation in the
l l
room.
Verify respect of the minimum recommended maintenance
l l
space.
OUTDOOR UNIT
AVOID:
Direct sunlight or area where hot air from exhaust fans
l l
investing the unit.
DO:
Choose a place as cool as possible and well ventilated.
l l
THE EXTENSION KITS ARE SUPPLIED PRECHARGED
Before the installation, verify that they are fit for the unit.
NARROW TUBE
OUTSIDE DIA.
6,35 mm
POWER SUPPLY 220 / 240V ~ 50 Hz

TOOLS REQUIRED FOR INSTALLATION (NOT SUPPLIED)

Phillips head screw driver
l l
wrench
21 mm wrench
l l
ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)
Synthetic oil HAB - Alkylbenzene type ex. EXXON ZERICE S, about 30 gr.
l l
PVC pipe to insulate hole in the wall, external diameter 50 mm. of minimum length as for thickness wall.
l l
2
To install in areas where
l l
Direct sunlight or near by heat
l l
Installing unit
l l
LARGE TUBE
OUTSIDE DIA.
7,93 mm
Tape measure
Level
l l
l l
24 mm wrench
Hammer
l l
l l
ACCESSORIES SUPPLIED WITH THE UNIT
PARTS
CONNECTION EXTENSION KITS -
LENGHT OF 2 OR 4 m
ACCESSORY SUPPLIED ON REQUEST
PARTI
Hammer drill
Hole saw or key hole saw ø 50
l l
l l
Hacksaw
Core bits 10 mm diameter drill bit.
l l
l l
FIGURE
NR°
REMOTE
UNIT CONTROL
1
RAWL PLUG S X 5
2
SCREW 4,2x32
2
WASHER
2
PLASTIC PLUG
(MALE AND
2 + 2
FEMALE)
RAWL PLUG
2/3
S X 10
SCREW 7x65
2/3
WASHER
2/3
OUTDOOR UNIT
BASKET OR
1
SUPPORT
FIGURA
EXTENSION KIT
FOR CONNEC-
1
TION TUBE
CONNECTIONS
1
PLASTIC BOX
RAWL PLUG
3
TAPPING SCREW
3
ø 3,5 x 45
CLAMP
2
19 mm
l l
(TO BE CONTINUED AT PAGE 3)