BLUE'LOG EXPANSION (MX MODULES)
The blue'Log base device can be expanded to provide additional interfaces using
various expansion modules (MX modules). For installation information, see the
EN
operating manual for blue'Log XM / XC or the instructions for the relevant MX module at
in the section "Photovoltaic
https://www.meteocontrol.com/en/services/downloads/
Monitoring – Products".

POWER SUPPLY

The current consumption of the blue'Log must be restricted by using an energy-limited
circuit. A DC source with limited power may also be used.
The power supply of the blue'Log must meet the following requirements:
Device protection
Voltage: 24 V DC | Current: 3.3 A
You will find details of device protection and further connection options in the operating
manual of blue'Log XM / XC.
ASSIGNMENT OF CONNECTIONS
The specific connection parameters of the devices to be installed (e.g. inverters, energy
meter, sensors) can be found in the "Compatibility list – blue'Log XM / XC" and the
manufacturer's instructions for the relevant device.