PROGRAMMING INSTRUCTIONS -
BASIC SETTINGS
Before entering the programming mode, make sure that
the appliance is in service mode.
In case no button is pressed in a period of 5 min, the
control panel will automatically return to the service mode;
any changes made will NOT be saved!
1. Press the scroll
button and hold it for 2 sec until the
display shows:
Language:English
Press the up
or down
language.
2. Press the scroll
button again; the display will show:
Set time:
Press the up
or down
day.
3. Press the scroll
button again; the display will show:
Rech. daily: ON
Press the up
activate/deactivate the daily recharge of the
compressed air chamber.
4. Press the scroll
button again; the display will show:
Interval:4 Days
Press the up
or down
of days between regenerations.
5. Press the scroll
button again; the display will show:
Exit
Press the up
or down
into the NOVRAM® and exit the programming mode.
The filtration capacity of the appliance mainly depends
on the daily water usage and the iron/manganese content
in the water; many other factors may also have a significant
impact on the filtration capacity. Therefore it is
recommended to regenerate the appliance on a regular time
basis. In most applications a regeneration every 3 to 4 days
should be sufficient.
In case of excessive:
iron/manganese content,
­
water consumption,
­
amounts of organic matter or suspended solids,
­
it is recommended to lower the regeneration interval to 1 or
max. 2 days.
EN - English
ELECTRONIC CONTOL PANEL
button to set the
8:01
button to set the time of
or down
button to
button to set the number
button to save the settings
PROGRAMMING INSTRUCTIONS -
CONFIGURATION PARAMETERS
Before entering the programming mode, make sure that
the appliance is in service mode.
All configuration parameters on this appliance have
been pre-programmed in the factory, to offer optimal
performance in a wide range of applications and situations.
Nevertheless it may be necessary or desirable to change any
of these parameters, to further optimize the appliances
performance or to adapt it to the specific requirements of
the installation.
In case no button is pressed in a period of 5 min, the
control panel will automatically return to the service mode;
any changes made will NOT be saved!
1. Press the scroll
display shows:
System Check
2. Within 10 sec, press the up
show:
Units:Metric
Press the up
measure (Metric or US).
3. Press the scroll
MaintInt: 24mths
Press the up
maintenance reminder function by setting the
maintenance interval, or deactivate the maintenance
reminder function.
4. Press the scroll
Cycle 1:
Press the up
of the regeneration cycle.
Press the scroll
regeneration cycle.
Cycle 1
Cycle 2
Cycle 3
Cycle 4
5. Press the scroll
Regen @
Press the up
regeneration.
6. Press the scroll
Exit
Press the up
into the NOVRAM® and exit the programming mode.
Page 12
button and hold it for 6 sec until the
button; the display will
or down
button to set the units of
button again; the display will show:
or down
button to activate the
button again; the display will show:
XX min
or down
button to set the length
button again to advance to the next
Backwash
Air intake
Fast rinse
No function (PF-OXY1,5)
button again; the display will show:
0:00
or down
button to set the time of
button again; the display will show:
or down
button to save the settings