Safety Instructions For Operation; Installation; Introduction - Installation - Husqvarna EPOS Reference station Manuel D'utilisation

Masquer les pouces Voir aussi pour EPOS Reference station:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 51
CAUTION:
Used if there is a risk of
damage to the product, other materials or
the adjacent area if the instructions in the
manual are not obeyed.
Note:
Used to give more information that is necessary
in a given situation.

38.2 Safety instructions for operation

38.2.1 Use
The product may only be used with the equipment
recommended by the manufacturer. All other types
of use are incorrect. The manufacturer's
instructions with regard to operation/maintenance
must be followed precisely.
The product may only be operated, maintained and
repaired by persons that are fully conversant with
its special characteristics and safety regulations.

39.1 Introduction - Installation

WARNING:
safety chapter before you install the product.
CAUTION:
Use original spare parts and
installation material.
Note:
Refer to www.husqvarna.com for more
information about installation.
39.2 To examine where to put the
reference station
CAUTION:
If there is a lightning rod
near by, do not install the reference station
higher than the lightning rod.
CAUTION:
Do not install the reference
station on a flagpole. Movements of the
reference station will affect the correction
data sent to the product with the accurate
position.
Install the reference station on a fixed object that
cannot not move or rotate.
1512 - 001 - 11.11.2020

39 Installation

Read and understand the
Please read the Operator's Manual carefully and
make sure you understand the instructions before
using the product.
Husqvarna does not guarantee full compatibility
between the product and other types of wireless
systems such as remote controls, radio
transmitters, hearing loops, underground electric
animal fencing or similar.
It is not permitted to modify the original design of
the product. All modifications are made at your
own risk.
The operating temperature is -20°C to 45°C / -4°F
to 113°F. The storage temperature is -20°C to
70°C / -4°F to 158°F.
38.2.2 In the event of a thunderstorm
To decrease the risk of damage to electrical
components in the reference station, we recommend
that the power supply to the reference station is
disconnected if there is a risk of a thunderstorm.
Connect the power supply again when there is no a risk
of thunderstorm.
Install the reference station on a post or a wall.
The post must be 32-55 mm / 1.26-1.37 in. in
diameter to fit the attachments on the reference
station.
Note:
If the reference station is installed on a
wall the top of the reference station must be above
the wall. There must be no metal in the wall.
The reference station needs to have full view of the
sky. The sky must be visible without obscuration in
all directions above 10° elevation angle.
160°
10°
Install the reference station at minimum 2.5 m / 8
ft. height.
The maximum distance between the reference
station and the product is 500 m / 1640 ft. when
free line of view. Objects between the reference
station and product decreases the distance.
10°
Installation - 43

Publicité

Table des Matières
loading

Table des Matières