Menu navigation

Standby time (temperature deactivation)
Reducing the set nominal temperature to 150°C (300°F)
(Standby).
The setback time after which the soldering station switches
to Standby mode can be set to between 0 and 99 minutes
(0=OFF). The setback state is indicated by a flashing actual value
display and is cancelled by pushing a button. The set value is briefly
displayed. The „Auto off" function is activated after three times the
setback time. The soldering tool is switched off (flashing bar on
display).
Offset (temperature offset)
The actual soldering-tip temperature can be adapted by
entering a temperature offset around ± 40 °C (± 72 °F).
Temperature version °C/°F (temperature units)
Switching the temperature display temperature unit from °C
to °F and vice versa.
Password (lock function)
Locking the nominal temperature. It is not possible to change set-
tings on the soldering station after the temperature has been locked.
Locking/ unlocking the soldering station: enter the code (1-999) using
the UP/DOWN buttons. To confirm, push the UP/DOWN buttons simul-
taneously for 3 sec.
If you lose your access code, please contact Weller's Customer Service.
(technical-service@weller-tools.com)
Temperature window (WINDOW)
Limiting the temperature range to max. ± 99 °C (178 °F)
based on a temperature locked using the „LOCK" function.
The locked temperature therefore represents the middle of
the adjustable temperature range.
factory setting
Resetting all setting values to 0, temperature 350°C / 660°F.
To confirm, push the UP/DOWN buttons simultaneously for 3 sec.