Safety advice
· Assembly and installation solely by instructed and
authorised skilled personnel in compliance with
the relevant regulations EN 1717 and EN 806/ DIN
1988-100 or the respective national regulations
· In public establishments and care facilities, any
additional relevant regulations must be followed
· Children and persons with restricted physical,
sensory or other mental capabilities must be fami-
liarised with use of the product or supervised in
a suitable way when using the product. Children
must not play with the product
· Use original spare parts and accessory parts only
· Use only HEWI mounting materials
· Flush the pipe system thoroughly before installation
· Not suitable for pressureless storage tanks
· Use for drinking water pipes in indoor area with
normal room climate (0 °C- 35 °C)
· All installation and maintenance work may only
be carried out in a de-energised condition (safely
disconnected from the power supply)
Bathroom zones
· The fitting may be installed in protection area 2
· The socket must be located outside of protection
area 2
· To avoid potential contact with water, plug in the
mains plug in dry indoor rooms in protection area
3 only
Montagehinweis | Mounting information | Consigne de montage | Montagetip
Indicazioni per il montaggio | Indicaciones de montaje | Wskazówki do montażu
2
3
Technical data:
Voltage supply with plug-in power supply unit:
100-240V AC, 50-60Hz/6.75 V DC
Voltage supply with battery:
6V lithium battery Type CR-P2
Output: 2.4W
Thermal disinfection:
possible, to DVGW W 551 (70°C)
Hot water inlet temperature: max. 70°C
Protection class - Power supply unit: IP40
Protection class - Plug-in connection: IP68
Minimum operating pressure: 0.05MPa
Maximum operating pressure: 0.8MPA
Flow rate (constant): 5.0 L/min
Risk of injury from electric shock! Mounting
by authorised qualified electric ians only in
compliance with the applicable regulations,
especially regulation VDE 0100, Part 701 or the res-
pective national regulations. Failure to comply voids
warranty and liability obligation.
Observe notes in separately enclosed
instructions, e.g. care tips, sensor
setting or in the HEWI Online
catalogue.
Disclaimer
HEWI does not accept any liability whatsoever for
personal injuries or damage to property that is or
has been caused due to incorrect assembly, ins-
tallation or use, especially due to disregard of the
listed warnings and safety instructions.
Disposal
Proper disposal is subject to the applicable national
statutory regulations. Electronic components must
be disposed of in a communalcollection point for
hazardous electrical waste.
For further information, please contact HEWI
Technical Support, tel. +44 1634 258200 (UK),
+49 5691 82-0 (International).
HEWI | 3