8
Tighten the strain relief screws.
A
B
C
A. In-Line Blower wiring
conduit (not incluided)
B. 6-9 wire connector
C. Hood Insert
Blower Connector
D. Strain reliefs
9
Remove the strain relief of the Range Hood terminal box,
and run trhough the green (or green/yellow) ground
wire from the wiring conduit. Install and tighten the
removed strain relief.
A
B
C
A. In-Line Blower wiring conduit
(not incluided)
B. 6-9 wire connector
C. Hood Insert
Blower Connector
D. Range Hood strain relief
E. Strain relief
10 Connect the wires from the 9-wire connector assembly
to the wires from the wiring conduit inside the range hood
terminal box.
11
D
12 Connect the home power supply wiring to the range
E
D
13 Reinstall the range hood terminal box cover.
14 Reconnect power.
Connect the same color wires to each other (black to
black, white to white, etc.) using UL listed wire connectors.
NOTE: Connect the green (or green/yellow) ground
wire from the wiring conduit to the green (or bare)
ground wire from the home power supply and to the
and to the green/yellow ground wire from the 9-wire
connector assembly (H) using UL listed wire connectors
(see the "Make Electrical Power Supply Connections
to Range Hood" section in the range hood installation
instructions).
B
A
A. Strain relief
G. Gray wires
B. UL listed wire
H. Green (or yellow/
connectors
C. Black wires
D. White wires
I. Motor electrical plug
E. Red wires
F. Blue wires
hood following the instructions that are supplied with
the range hood.
C
D
E
F
G
H
I
green) and green /
yellow wires
cable
13