INSTALLATION GUIDE

BEFORE INSTALLATION

Parts

Check that the following parts are included in the packaging:
1
Figure 1: Sauna heater parts
1. Sauna heater
2. Herb bowl / air humidifi er
3. Heater Mounting Brackets x 4
4. Warning and Caution plates for the room in multiple languages
5. Bracket screws x 4
6. Connectors x 3
7. Lock screw B 8 x 9.5 x 1
8. Screws B 4 x 6.5 x 6 for Warning and Caution plates
Contact your dealer if anything is missing.

Installation requirements

To ensure safe use of the heater, check that the following criteria
are met:
Electrical wiring should be installed in accordance with NEC
and all state and local codes.
Fuse size (A) and power cable size (AWG) must be suitable
for the heater (see The section called Connection/wiring
diagram, Page 3.
The sauna ventilation must comply with the instructions in
this manual (see The section called Positioning the inlet vent,
Page 2, The section called Positioning the outlet vent, Page
2).
The position of the sauna heater must comply with the in-
structions in this manual.
The heater output (kW) must be suitable for the sauna
volume (cu.ft.) (See Table 1, Page 1). The minimum and
maximum volumes must not be exceeded.
Table 1: Voltage and sauna volume
Model
Voltage
SSU 5
208 V
SSU 5
240 V
SSU 7
208 V
SSU 7
240 V
SSU 8
208 V
SSU 8
240 V
5
2
4
3
6
7
8
Sauna volume
Sauna volume
min. cu.ft.
max. cu.ft.
100
180
100
210
175
265
175
310
250
360
250
425

Installation tools

The following tools and materials are needed for installation and
connection:
level,
adjustable spanner wrench,
electric drill,
screwdriver.
Planning heater and room installation
Before starting to install your sauna heater:
Plan where to position the sauna heater (see The section
called Positioning the heater - normal installation, Page 1).
Position the inlet vent (see The section called Positioning the
inlet vent, Page 2).
Position the outlet vent (see The section called Positioning
the outlet vent, Page 2).
Plan the electrical installation (see The section called Con-
nection/wiring diagram, Page 3).
Positioning the heater in a sauna room
Position the sauna heater:
On the same wall as the door (or the side wall if very close to
the door wall).
At a safe distance from the fl oor, side walls and interior
fi ttings (see Figure 2, Page 1).
1
Figure 2: Positioning the heater - normal installation
1.
Minimum distance from side wall: 3.0 in
2.
Minimum distance from ceiling: 44.0 in
3.
Minimum distance from interior fi ttings: 4.0 in
4.
Minimum ceiling height: 75.0 in
5.
Minimum distance: 1.0 in
6.
Minimum distance from interior fi ttings: 2 in
7.
Distance from fl oor: 7 in
1
2
3
4
6
5