Simu T5 AUTO SHORT Hz Notice Originale page 7

Masquer les pouces Voir aussi pour T5 AUTO SHORT Hz:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1
If you do not want to use this transmitter as the individual control:
- cut the power supply (2 seconds minimum).
- repeat the opération 4.1* with a new transmitter and then go to step §5.
* In this case, the motor will run for 0,5 second in both directions, that means the limits setting is already done.
Programming the first individual control point
5
This operation can only be performed from the transmitter that was used for operation 4.1.
- Press the transmitter PROG Key for approximately one
second. The motor will run for 0,5 second in one direction
and then in the other.
Your transmitter is now programmed to control the motor in
stable mode.
6
Programming a new (individual, group or general) control point
6.1- Open the memory of the receiver from the control trans-
mitter:
- Press the PROG key of the transmitter for about 3 seconds.
The motor will run for 0,5 second in one direction and then in the
other.
6.2- Confirm the operation from the new transmitter you want
to program:
- Press the PROG key of the transmitter for 1 second. The motor
will run for 0,5 second in one direction and then in the other.
- For group controls, repeat operations 6.1 and 6.2 for each motor in the group.
- For general controls, repeat operations 6.1 and 6.2 for each motor in the installation.
- To delete an transmitter from the memory of a motor, perform operations 6.1 with a programmed transmitter, then
perform the operation 6.2 with the transmitter to be deleted.
7
Recording / controling / deleting intermediate position
Recording:
- Move the motor to the wanted
position.
- Press 5 seconds on the "Stop"
key. The motor will run for 0,5
second in one direction and then
in the other.
Deleting :
- Position the motor on the intermediate position. Press 5 seconds on the "Stop" key, the intermediate position is
deleted.
1
Control:
- Press the "Stop" key for
0,5 second. The motor
runs to the intermediate
position.
5s
PROG 1s.
1
2
PROG ≥ 3s.
1
2
PROG < 1s.
0,5s
>>
>>
>>
3 / 4

Publicité

Table des Matières
loading