Notes regarding the operating manual ............................ B - 1
Safety ............................................................................. B - 1
Technical data ................................................................ B - 1
Description of the device................................................. B - 2
Operation........................................................................ B - 2
Maintenance and repair .................................................. B - 3
Disposal.......................................................................... B - 3
Declaration of conformity ................................................ B - 3
Notes regarding the operating manual
Symbols
Danger!
Warns of a hazard which can lead to injuries.
Caution!
Warns of a hazard which can lead to damage to property.
Legal notice
This release replaces all previous versions. No part of this
publication may be reproduced without written permission from
®
TROTEC
. The same applies for electronically processing,
duplicating or spreading the publication. Subject to technical
changes. All rights reserved. Trademarks are used without
guarantee that they may be used freely and primarily following the
spelling of the manufacturer. Product names are registered.
Changes to construction in the interests of constant improvements
to the product, as well as changes to the shape and colour are
reserved. The scope of delivery may vary from product images.
This document was created with all due care. TROTEC
no liability whatsoever for possible mistakes or omissions. ©
®
TROTEC
EN
Safety
Intended use
This device is exclusively intended for measuring temperature
with an infrared sensor in the measuring range specified in the
technical data. People who use this device must have read and
understood the operating manual, especially the "Safety" chapter.
Improper use
The device must not be used in potentially explosive atmospheres.
It may not be pointed at people.
®
TROTEC
accepts no liability for damages resulting from improper
use. In such a case, entitlements to a warranty are forfeited.
Danger!
• Keep a sufficient distance away from sources of heat.
Caution!
• Do not use abrasive cleaners or solvents to clean the device.
• Do not leave the packaging lying around. Children may use it
as a dangerous toy.
• Measuring devices are not toys and do not belong in the hands
of children.

Technical data

Model
Dimensions H x W x D
®
Measuring range
accepts
Accuracy
Measuring range resolution
Relative humidity during operation Max. 90 % relative humidity
Distance to measuring spot
diameter ratio
Reaction time
Power supply
Switch off
Storage
Operating manual - Infrared thermometer BP05
BP05
90 x 20 x 20 mm
-35 °C to 230 °C (-31 °F to 446 °F)
± 2 % (±4 °F) or 2.0 % of the measured
value (the higher value applies)
0.1 °C / °F
1:1
< 1 s
two 3 V LR44 batteries
After approx. 15 seconds of non-use
-10 °C to 60 °C (14 °F to 140 °F) at
max. 80 % relative humidity