Problem
Smoke retreat into the room
with the fireplace door open
Phenomenon of insufficient
heating or extinction of the
fireplace
Phenomenon of insufficient
heating despite good com-
bustion in the combustion
chamber
Excessive soiling of the
chimney flue liner glass
The proper functioning of the cartridge may be impaired by atmospheric conditions (humidity,
fog, wind, atmospheric pressure), and sometimes by near-located tall objects. In case of repeated
problems, it is necessary to ask for an expert opinion from a chimney sweep company or use a chimney
cowl (e.g. firefighter).
SERVICE AND MAINTENANCE OF THE FIREPLACE STOVE
All repairs should be entrusted to an authorized installer and use spare parts of the cartridge manu-
facturer. Any changes to the construction, installation and use rules are not allowed without the ma-
nufacturer's written consent. All maintenance operations may be carried out only when the fireplace
stove is in a cooled condition, using protective gloves. The fireplace stove, flue pipe, connecting pipe
and chimney must be cleaned regularly.
In the event of a prolonged interruption in the operation of the fireplace stove, check the chimney
as it may have become clogged. Periodic or scheduled maintenance of the fireplace stove includes:
- Ash removal, windscreen cleaning, flue pipe cleaning;
- periodically clean the firebox of the fireplace stove (the frequency of this operation depends on the
type and humidity of the wood used);
- use a poker, scrapers, brush to clean cast iron components;
18
Possible cause
- Rapid door release
- Closed windshield
- Poor room ventilation
- Inappropriate smoking
technique
- Poor chimney draught
- Bad weather conditions
- Low fuel consumption
- Too much wood humidity
- Too little chimney draught
- Inappropriate external air
supply
- Closed air damper
- Low calorie wood
- Too much moisture in the
wood used for combustion
- Too shredded wood
- Low-intensity combustion
- Use of coniferous resinous
wood as fuel
Recommendations
- Open the door slowly
- Open the sunroof
- Ensure that the room is adequ-
ately ventilated in accordance
with the instructions
- Refuellate after obtaining the
ignition layer
- Check the chimney
- Install an exhaust fan or use a
flue cowl (e.g. firefighter)
- Load the fireplace according
to the instructions
- Use wood with humidity up
to 20%
- Check the chimney
- Clean the duct and the air
supply grille
- Open the air damper
- Use wood according to the
instructions
- Use wood with humidity up
to 20%
- Use the pliers specified in the
instructions
- Use only dry wood. Adjust the
amount of combustion air
- Use the wood provided for in
the manual