Connection
■ Terminal names
@ Fuse (30 A × 2)
# Battery terminal
$ Ground terminal
^ Amplifier A/B speaker output
terminals
• Stereo Connections:
When you wish to use the unit as a stereo
amplifier, stereo connections are used.
The speakers to be connected should
have an impedance of 2Ω or greater.
When multiple speakers are to be
connected, ensure that the combined
impedance is 2Ω or greater for each
channel.
• Bridged Connections:
When you wish to use the unit as a high-
output monaural amplifier, bridged
connections are used. (Make connections
to the LEFT channel 9 and the RIGHT
channel · SPEAKER OUTPUT terminals.)
The speakers to be connected should
have an impedance of 4Ω or greater.
When multiple speakers are to be
connected, ensure that the combined
impedance is 4Ω or greater.
2CAUTION
The rated input of the speakers should be no
less than the maximum output of the
amplifier. Otherwise malfunction may result.
& Amplifier SUB speaker output
terminal
As this unit accepts speakers with a
minimum impedance of 2 ohms, connect
speakers with 2-ohm or higher impedance
to these terminals.
POWER IN
SPEAKER
OUTPUT
BATT.
P.CON
@
# $ %
A.CH
FILTER
B.CH
B.M.S.
OPERATION
INPUT SELECTOR
OFF
OFF
A
B
OFF
HPF
STEREO
MONO(Lch)
HPF
LPF
REMOTE
+12dB
50
200
50
200
50
200
50
200
A.CH HPF
B.CH HPF
B.CH LPF
SUB.CH LPF
FILTER FREQUENCY(Hz)
BRIDGED
LEFT
RIGHT
SUB
A
B
SUB
^
&
LINE IN
EXT.AMP.CONT.
A
B
SUB
A
A
B
SUB
L
L
GND
R
R
*
(
)
* RCA cable ground lead terminal
When using an RCA cable with a ground
lead attached, connect the ground lead to
this terminal.
( A.CH/B.CH/SUB.CH LINE IN
terminal
% Power control terminal
Controls the unit ON/OFF.
NOTE
Controls the unit power. Be sure to connect it
with all the systems.
) EXT.AMP.CONT. (external
amplifier control) terminal
Controls the B.M.S. Only Kenwood center
unit models sold in 1999 or later with a
"EXT.CONT."/"EXT.AMP.CONT." wire
attached can be used.
Also, a maximum of 3 power amplifiers can
be operated at the same time.
NOTE
There are cases when operation may not be
possible due to wiring wire type and length.