c
CAUTION!
HEATER
CONNECTIONS. COMPARE
WITH THE INSTALLATION
NOTE ATTACHED TO THE
DEVICE IN THE FACTORY!
KW = Cold water
WW = Hot water
ZL = Circulation (optional)
F1 = Probe pin 1
F2 = Probe pin 2
WVL = Supply heating coil
WRL = Return heating coil
EHP = E-heating cartridge
(optional)
FL = Flange/inspection port
25
Aquarea Tank
GB
GB
Technical Data
(GB)
Nominal volume
Diameter
Height
Diagonal height
Weight
Connection size
Cold water
KW
Hot water
WW
Connection size
Heating supply
WVL
Heating return
WRL
Heating
F1
Heating
F2
FL
Blind flange
TK
Heating surface
Continuous output
tCW=10°C
tHW=45°C
Content of the heat exchanger
Performance indicator
tCW=10°C
Insulation strength
Perm. excess operating
Heating water
pressure
Potable water
Perm. operating temperature
Heating water
Potable water
IG = Internal thread / AG = External thread
* Subject to change! This thermal insulation is mounted subsequently and can vary. For more information please read separate instruction
manual.
** Without thermal insulation.
*** Vertical external sensor.
Typ
W 300
W 500
Ltr.
288
440
D
mm
700
H
mm
1294
1921
N
mm
1393
1990
kg
139
222
R
1"
A
mm
55
J
mm
1229
1853
R
11/4"
F
mm
784
1279
B
mm
220
C
466
699
G
mm
874
1369
mm
150
L
mm
275
mm
450
m²
3,2
6,2
kW
68
131
l/h
1666
3222
l
24
43
11,5
33,5
M
mm
50
bar
10
bar
10
°C
110
°C
95
Aquarea Tank
26