5.5.2 Loaded Voltage Test
Rev engine to
2,500 - 3,000 RPM
Switch headlights to
high beam
1. Ensure all vehicle accessories are turned OFF
2. Switch headlights to high beam
3. Hold engine revs between 1,500-2,500 then press
4. Maintain engine revs until countdown timer reaches zero.
Timer countdown
from 10s to 0s
5. When timer reaches zero the results will automatically be displayed
6. After 3 seconds the display will automatically move to the next test:
5.5.3 Diode Ripple Test
1. Press
to start test
Engine idling speed
2. Ensure all vehicle accessories are turned OFF
3. Switch headlights to high beam
4. Leave engine idling (should be between 700 - 1,000 RPM) then press
5. Wait until countdown timer reaches zero
Timer countdown
from 10s to 0s
6. When timer reaches zero the results will automatically be displayed
10422 RMM500 Instructions UK 140x170mm 15pp MULTI LANGUAGE.indb 10
Turn air conditioning OFF
Hold accelerator for 10 seconds
Rev engine up to about
2,000 RPM and hold for
10 seconds
Turn air conditioning OFF
Switch headlights to
high beam
10