The inputs support the reception of the DVB-S/DVB-S2 satellite signals and they can power supply an LND
remotely; they support the management of DiSEqC control, version 1.0.
input independently, using the four upper connectors, or the loop-through function can be used, which enables
providing a signal received from one of the subsequent inputs in cascade. In this case, the cascade inputs
cannot have the reception polarity/band specified, because the signal that can be used will be the same as
the input used as source for the
The LNB remote power feed is able to supply a maximum current of 400 mA, total for all the inputs. If this
limit is exceeded, a current limiter triggers, which temporarily deactivates the remote power feed on all the
inputs, reactivating them one at a time, until the input (or inputs) causing the problem is identified. The remote
power feed and reception from these inputs is finally deactivated, while the loop function remains active. The
red led then lights up corresponding to the overloaded input. Reception from the error inputs can be reset
after solving the system malfunction, deactivating and reactivating the input, or by restarting the
FTA.
D-MATRIX-4S FTA
has four multicolour leds on the top (one for each input), to indicate the sat signal
reception status, and one multicolour led on the bottom showing the system status.
The following table gives a useful summary to interpret the lighted leds.
LED COLOURS OF INPUT STATUS
Off: input off
Orange
Input active waiting to lock
Green:
Input active and locked
Red:
Input overloaded
LED COLOURS OF SYSTEM STATUS (during initialisation)
Orange: boot system
Red: begin applications
Green: system started without errors
LED COLOURS OF SYSTEM STATUS (system started)
Green: normal
Orange: anomaly
Flashing red: update and/or recovery phase
RF INPUTS VIEW
loop.
MULTICOLOUR STATUS LEDS
The signal can be provided to each
12
D-Matrix-4S