GENERAL FEATURES

The FWECSA controller is designed to control all of
the system units in the Daikin range with multi-speed,
single-phase motor or coupled to an inverter for speed
modulation.
The FWECSA controller system is composed of:
I/O board containing the power supply circuit,
the microprocessor system and the connectors
(unscrewable) to connect the input and output devices;
User unit composed of graphic display and keyboard
(six keys) equipped with clock and probe to read the
room temperature.
The connection between the I/O board and the
user unit is set up using the relative connectors
and a data transmission cable fitted with a pair
of twisted conductors and shielding.
The controller makes serial communication possible on two
types of networks:
External Supervisor System solution: connection
to an external supervision system with MODBUS RTU
protocol on serial RS485;
SMALL solution: connection of multiple FWECSA
controllers in two possible configurations:
-
MASTER/SLAVE on serial RS485
-
MASTER/SLAVE on CW (Conveyed Waves),
which can also be set up with External Supervisor
System solutions.
Mixed net solution: connection of multiple FWECSA
controllers on different levels :
-
MASTER/SLAVE on serial RS485 (external
supervisor system or FWECSA),directions to the
slaves RS485 (called zone MASTER)
-
zone MASTER FWECSA , receiving directions from
NET MASTER RS485,transmitting directions to
SLAVES OC
-
NET SLAVES OC, working exactly to the ZONE
MASTER
FC66003946
Rev 00
Controller for units
USER MANUAL
It is strictly forbidden to reproduce this manual, even partially

MAIN FUNCTIONS

Automatic or manual fan speed variation (selected
from the keyboard);
Management of ON/OFF or modulating valves for two
or four-piped systems.
SUPPORTING electric heater control, used during
heating;
SUMMER/WINTER mode switch (= cooling/heating)
in four possible ways:
-
manually, from the keyboard;
-
manually, remotely (from digital input);
-
automatically, depending on water temperature;
-
automatically, depending on air temperature.
dehumidification function control;
operation with TIME SLOTS.
It is also supplied with:
External pre-consensus digital input (for example:
window contact, remote ON/OFF, presence sensor, etc.)
that can enable or disable unit operation (contact logic:
see board configuration parameters);
Digital switching input Remote centralised Cooling/
Heating (contact logic: see board configuration
parameters);
Digital input to enable ECONOMY function from
remote control (contact logic: see board configuration
parameters);
Water temperature probe (accessory), one or two
(optional with 4-pipe systems);
STANDARD room air temperature probe (installed
inside the user unit);
Remote room air probe (accessory) that can be used,
if connected, in place of the standard one installed in
the user interface;
Remote relative room air humidity probe (accessory);
A completely configurable digital output (dry contact).