Menu 1
Pressing the Menu button takes you to menu 1
Standby Temp.
The standby temperature is a preset value to which a soldering tool is adjusted when not in use.
Option
Description
OFF
Standby deactivated (factory setting 180°C (360°F)
100-300 °C
Standby Temp., Individually adjustable
200-600 °F
Standby time (temperature deactivation)
On soldering tools with a usage sensor in the handle, the soldering tool is adjusted to the standby tem-
perature after the preset standby time if not in use. The sensor integrated in the tool detects changes
in status and deactivates standby mode as soon as the tool is moved.
On soldering tools without a usage sensor, the soldering tool is adjusted to the standby temperature
after the preset standby time if no soldering process is being performed.
Pressing the UP and DOWN buttons exits standby mode.
Option
Description
OFF
Standby deactivated (factory setting 2 min)
1-99 min
Standby Time, Individually adjustable
OFF time
If the soldering tool is not in use, the heating for the soldering tool is deactivated after the OFF time
elapses. Temperature deactivation is performed independently of the set standby function. The actual
temperature is indicated by flashing LED and serves as a residual heat display. The display reads
„OFF".
While the soldering tool cools, the residual heat is displayed.
Cooling also flashes in the display.
As soon as the temperature falls below 50 °C (122 °F), OFF appears in the display and the backligh-
ting is deactivated.
Pressing the UP and DOWN buttons at the same time exits OFF mode.
Option
Description
OFF
OFF time Deactivated (factory setting 10 min)
1-999 min
OFF time, Individually adjustable