maintenance work will be done exclusively after disconnecting the pump from the mains. Make sure that it can not
be turned on accidentally.
This product and its components must be disposed of in accordance with environmental regulations. Use local public
or private waste-collection systems.
13.1 Periodical checks
In its normal operation, the electro-pump requires no maintenance. However, it is recommendable to make a
periodical check of the absorbed current, the manometric drive pressure with the mouth closed and at maximum
flow, in order to locate faults or wear in time. If possible, have a programmed maintenance plan to achieve a
problem-free operation without long, costly repairs and causing minimum pump expense and downtime.
14 - MODIFICATIONS AND SPARES
Any modification made without previous authorisation releases the manufacturer from all liability. All
spares used in repairs must be original, and all accessories must be authorised by the manufacturer in
order to guarantee complete safety for people and the operators of machines and installations that use
the pumps.
15 - TROUBLESHOOTING
Faults
1. The motor does not start and
makes no noise
2. The motor does not start, but
makes a noise.
3. The motor turns with difficulty
Checks
A. Check the protection fuses
B. Check the electrical connections
C. Make sure the motor is receiving power
A. Make sure the supply voltage
corresponds to the voltage on the plate.
B. Make sure the connections have been
made correctly.
C. Check the terminal box for all phases.
D. The spindle is blocked.
A. Check the power supply, which may be
low.
B. Check for possible rubbing between
moving and fixed parts.
C. Check the state of the bearings
17
Solutions
A. If they are burned, replace them.
B. If the problem is solved immediately, it
means the motor is short-circuited.
B. Correct all possible errors
C. If not, reset the missing phase.
D. look for possible pump or motor
obstructions.Eliminate the obstruction.
B. Eliminate the cause of the rubbing.
C. Replace worn bearings.
ENGLISH