INTERCONNECTIONS:
JP2:
CONTROL PANEL
4-pole connector for control panel connections with
the special wire.
JP3:
TANKS
1. NEGATIVE
2. 1/3 drinking water tank
3. 2/3 drinking water tank
4. 3/3 drinking water tank
5. NEGATIVE
6. Recycle tank
AMPEROMETER
JP7:
4-pole connector for the connection of the
"Amperometer" accessory, if applicable, to combine
with the NE102 control panel for reading the service
battery loading and discharge current.
LIGHT OUTPUT
JP8:
1. NEGATIVE
2. EXTERNAL LIGHT (+)
3. LIGHTS_1 (+)
4. LIGHTS_2 (+)
JP9:
FRIDGE OUTPUT
1. NEGATIVE
2. Gas ignition power supply (+)
3. Output (+) AES fridge power supply
4. Output (+) three-way fridge power supply
OUTPUT D+
J3-J4 :
Positive output (Max 0.5A) to activate all loading
with engine running (e.g. AES fridge, antenna
retrieval, discharge valves, etc)
J2:
OUTPUT COUPLING RELAY COIL
CONTROL
Output (-) to control the coupling relay coil (RE7
fig. 5) if fitted externally.
JP10:
OUTPUT POWER SUPPLIES
1...5. NEGATIVE
6.
Output (+) power supply to PUMP
7.
Output (+) power supply to STEP
8.
Output D+ step return
9,10 Output (+) BOILER/HEATER
JP11: SERVICE BATTERY INPUT
1. Input + SERVICE battery (B2)
2. Input + SERVICE battery (B2)
3. Input POWER ON from battery charger TE43
4. NEGATIVE
JP12: CAR BATTERY INPUT
1. Input + CAR battery (B1)
2. Input + CAR battery (B1)
3. Input D+ from alternator or engine ignition key
contact
4. NEGATIVE