Troubleshooting; Care And Cleaning - TOOLCRAFT TC-AHR 9 Notice D'emploi

Enrouleur pour tuyau d'air comprimé 9 m
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

12. Troubleshooting

Always disconnect the product from the compressed air supply before carrying out any maintenance or
repair work.
Fault
The hose does not wind
back onto the drum fully.
The hose doesn't click
into place.
Air escapes from an
unsealed part.

13. Care and cleaning

Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these could damage the
housing or even impair the functioning of the product.
• Only use mild detergents to clean the compressed air hose.
• Use a dry, lint-free cloth to clean the frames and hose drum.
20
Possible cause
• The hose was rolled too quickly.
• The hose was not rolled evenly.
• The spring force is too low.
• The replacement hose is too
heavy.
• The hose stop ring (4) was
adjusted.
• The hose reel was not installed
correctly.
• The hose was released too
quickly.
• The locking mechanism may be
faulty.
• The hose is damaged.
• The seal on the hose drum may
be worn.
• The hose clamp is not properly
secured.
Solution
• Roll the hose slowly.
• Roll the hose evenly.
• Increase the spring force or insert a new
spring.
• Use a replacement hose with a suitable
weight.
• Move the hose stop to the correct
position.
• See section 9 ("Installation") to check that
the product was mounted correctly.
• Hold the hose in your hand and slowly
guide it back onto the hose drum.
• Replace the locking mechanism.
• Replace the hose.
• Replace the hose clamp or secure it in
place.
• Contact a technician to replace the seal
on the hose drum.

Publicité

Table des Matières
loading

Produits Connexes pour TOOLCRAFT TC-AHR 9

Ce manuel est également adapté pour:

1499511

Table des Matières