MANUEL D'INSTALLATION
CAA360USBRS
USB or RS232 > RS-485 Converter
4] ACCESS CONTROL SYSTEM INSTALLATION
You have two options for connectiong the CA-A360-USBRS to the computer. You can
connect one end of the 6 pin cable that comes with the CA-A360-USBRS module
to the connector on the module. The other end of the 6 pin cable should be connected
to the serial communications port on the computer using the appropriate adapter
(9 and 25 pin adapters provided). Or you can connect a USB wire (not provided) from the
CA-A360-USBRS to the computer.
Connect the A+, B- and GND terminals of the CA-A360-USBRS module to the A1+, B1- and
GND terminals of the first controller using shielded, 4 wire, stranded cable (refer to Figure
1). The +12V and GND terminals of the CA-A360-USBRS should be connected to the
+12V and GND terminals of the CT-V900-A controller (refer to Figure 1).
Connect to PC (RS232 Port)
Connection au PC (Port RS232)
5] REPEATER MODULES INSTALLATION
Using the screw-in terminals, connect RX of the first CA-A360-USBRS repeater module
to TX of the 2nd module. Connect TX of the first module to RX of the 2nd module.
Ground terminal of the first module should be connected to GND on the 2nd module
(7.6m / 25ft maximum). Connect the A+, B- and GND terminals of each CA-A360-USBRS
module to the A1+, B1- and GND terminals of the appropriate controller using a shielded,
4 wire, stranded cable (refer to Figure 2). Power can be supplied by the model CT-V900-A
controllers or a separate power supply. When using a separate supply, connect the GND
terminal of the CA-A360-USBRS module to the negative terminal of the controller.
Figure 1: System Installation
USB
TX
RX
B-
A+
GND
EOL = ON
12V
CA-A360-USBRS
Connect to PC (USB Port)
Connection au PC (Port USB)
CT-V900-A Controller
Centrale CT-V900-A
EN
+12
GND
Z9-10
COM
Z11-12
Z13-14
COM
Z15-16
EOL = ON
If there is just
A1+
one controller (already = OFF)
B1-
EOL = ON
si il n'y a qu'une
GND
seule centrale (Sinon = OFF)
+12
GND
Z9-10
COM
Z11-12
Z13-14
COM
Z15-16
A1+
EOL = ON
B1-
On the last controller
EOL = ON
GND
sur la dernière centrale
3
cdvigroup.com