During use, the user and other persons standing nearby have to
wear suitable goggles, helmets, ear protectors, dust mask,
protective cloves and boots.
During manual operation, always hold the tool with both hands
and be fall-safe. Consider the tool's reaction torque in case of
blocking.
Always work with concentration. Always work in a carefully
considered way and do not use the tool if you are lacking
consideration.
Hold power tool by insulated gripping surfaces, when
performing an operation where the cutting accessory may
contact hidden wiring or its own cord.
contacting a "live" wire may make exposed metal parts of the power
tool "live" and could give the operator an electric shock.
For further safety instructions, see the enclosure.
The EHD 1500 is designed according to protective class II.
Prior to putting the tool into operation, check the mains voltage for
conformity with the requirements of the tool's nameplate.
Voltage variations between + 6 % and – 10 % are permissible.
The tool includes a start-up speed limiter to prevent fast expulsion fuses
from unindented responding.
Only use extension cables with a sufficient cross-section. A cross-section
which is too small could cause a considerable drop in performance and an
overheating of machine and cable.
Recommended minimum cross sections and maximum cable lengths
Mains voltage
110V
230V
Additional Handle
For manual drilling, the EHD 1500 may be used only together with its
additional handle which comes with the tools or in a drill rig. Place the
handle on the gearing collar from the front and fix it by counterclockwise
rotation.
Electrical Connection
Cross section in sq. mm
1.5
20 m
50 m
15
Cutting accessory
2.5
40 m
80 m