Rear part maintenance
GB
48
Partially incline the machine and extract the two
screws shown.
Extract the left side-panel.
Having removed the panel the plug and switch are
easily reached. Detach the multiple clamp (A) from
the switch, remove the protective liner (B) and
detach the single connections from the plug.
Inside the plug there are two 6.3 Ampére fuses.