WARNING: at re-start after every maintenance operation, when the filter's bowl is unscrewed from
head, change the o-ring with a new one and carefully lubricate with original lubricant Lubrikit before
tightening the bowl to the head. Make sure that there are no water leaks from the product and
especially control the tightening beteween the housing head and the housing bowl. Continue
checking that the tightening is good and there is no water leakage for 48 hours following the
installation and start-up. In case of leakage, open the housing, remove the o-ring from te bowl,
place a new o-ring and apply lubricant, then re-tighten the bowl to head and repeat the leakage
check as above. Use only original Altas Filtri o-rings, otherwise the warranty is void. Ask your Vendor
for original o-rings, Lubrikit and other spare parts.
Remark: after the maintenance, slowly turn on a water supply (tap) downstream the installed unit
and let the water flow for at least 5 minutes before the use.
WARNING: for persistent encrustations onto the filter net or if the pressure difference between the
two manometers remains above 1 BAR after cleaning the filter, replace the filter cartridge with a
new one.
WARNING: filter cartridges and the transparent bowl have an average working life, for that reason
we recommend replacing RLH and RSH plastic net cartridges at least every 24 months and RAH
stainless steel net cartridge at least every 48 months. The filter bowl must be replaced with a new
one at least every 5 years.
Follow the local regulation in force when disposing cartridges and bowls.
TROUBLESHOOTING
HYDRA filters are constructed following strict quality controls and are subject to stringent efficiency
and resistance tests. See here following a series of problems that may occur due to incorrect
installation or maintenance or improper use, possible negligence or due to filter or filter parts
comsumption.
PROBLEM
Water does not run from faucets
Unfiltered water runs from
faucets
The cartridge does not clean
during self-cleaning operation
Water leaks between the filter
head and bowl.
Water leaks from connections
between pipes and from the
sides of the filter
Water leaks between the bowl
and drain valve
DECLARATION OF COMPLIANCE
Manufacturer's address: ATLAS FILTRI srl - Via Pierobon 32, 35010 Limena (PD) - ITALY
HYDRA filters are constructed in accordance with the following European directives:
UNI EN 1717 - Protection against pollution of potable water in water installations and general
requirements of devices to prevent pollution by backflow
Warranties
- Keep the sticker placed onto the package to identify the product.
- In EU countries, the applicable warranty terms are those indicated in Directive 85/374/EEC as amended and in
Directive 1999/44/EC as amended. For extra UE Countries, the product is granted by a limited warranty for 12
months from the date of purchase proven by a regular receipt. The liability of Atlas Filtri S.r.l. is limited solely to
the replacement of proven defective product, excluding shipping, installation labour or other repair costs. No
warranty is given on filtration or any other performance as it may vary with local water conditions.
For any controversy whatsoever, Atlas Filtri S.r.l. elects the Court of Padova as the competent Bar, with the
application of the Italian Regulations and Laws.
CAUSE
- cartridge clogged;
- Bowl broken;
- cut-off valves and/or
By-pass closed.
- cartridge broken;
- spring broken;
- cartridge gasket ruined;
- by-pass valve open.
- insufficient pressure in the
bowl;
- cartridge not correctly
positioned in the bowl.
- Bowl o-ring ruined
- sealing tape
insufficient
- drain valve gasket damaged
REMEDY
- clean the cartridge following
the extraordinary
maintenance procedure;
- replace the bowl and o-ring;
- open the closed cut-off valve
or by-pass.
- replace the cartridge;
- replace the spring;
- replace the cartridge gasket;
- close the by-pass valve.
- check the drain pipe: if pinched or
bent, remove the problem;
- rotate the cartridge clockwise or
Counter-clockwise so that it moves
vertically without strain in the bowl.
- replace the o-ring.
- add a few turns of sealing tape
- replace the gasket.
- 8 -