Sprint Electric PL Guide De Démarrage Rapide page 12

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

7.
Motor 1/2 Select
8.
Speed Feedback Type
4.4.2 Feedback calibration
If you do not have a DC tachometer or encoder, skip this section. Save the parameters (section
3.1.2).
1.
DC tachometer
For a DC Tachometer, first calibrate the drive to the expected DC voltage for base speed
Base Tacho Voltage = (Base Speed/1000) x Tacho Volts per 1000 RPM
The tacho voltage must not exceed 200 Vdc
R-R-U-R-6xD-R-U/D
Then 4xL
2.
Encoder
PPR
If the encoder is a quadrature type then enable parameter 10 as below. For a pulse and
direction type encoder disable the parameter. In both cases set the number of lines.
Note:
On PL models only, it is also possible to operate with a pulse-only encoder (no
direction signal).
10
L-D-R-U/D
L-8xU-R-U/D
Then 4xL
R-R-U-R-8xD-R-R-U/D
L-D-R-U/D
Then 4xL
PL/X Quick Start Guide
20) MOTOR 1/2 SELECT
MOTOR 1
9) SPEED FBK TYPE
ARMATURE VOLTS
8) MAX TACHO VOLTS
87.50 VOLTS
10) QUADRATURE ENABLE
ENABLED
11) ENCODER LINES
1024

Publicité