DIP-SWITCH
On
AUTOMATIC
1
CLOSING
Off
On
2
2 / 4 STROKE
Off
On
PRE-
3
FLASHING
Off
On
NO
4
REVERSE
Off
On
SENSITIVE
5
EDGE
Off
On
6
MEMO
Off
IMPORTANT:
Each pair of terminals attached to an NC contact that is not in use must be short-circuited in
order to ensure the proper operation of the board.
The door's earthing system must comply with current standards. The manufacturer will accept
no liability for any damage deriving from failure to comply with this requirement.
7. 433.92 MHz BUILT-IN RADIO RECEIVER
The radio receiver can learn up to a maximum of 8 dip-switches (TXD2, TXD4, BUG2, BUG4, K-SLIM, K-SLIM-C,
T-4, T-4C) or rolling codes (BUG2R, BUG4R, K-SLIMRP, T-4RP).
The learning mode (dip-switch or rolling code) is determined by the first radio control device and remains un-
changed until all the codes have been cancelled.
LEARNING SYSTEM FOR RADIO CONTROL DEVICES
P-RX = OPEN/CLOSE
1_ press button P-RX briefly to associate a radio control device with the OPEN/CLOSE function;
2_ LED DL4 turns off to indicate that the code learning mode has been activated;
3_ press the button of the relative radio control device;
4_ LED DL4 turns on again to indicate that the code has been memorised (if this does not happen, wait 10
seconds and start again from point 1);
5_ to memorise codes to other radio control devices, repeat the procedure from point 1 up to a maximum of
8 transmitters;
6_ to exit the learning mode without memorising a code, press button P-RX briefly.
Note: if the maximum number of codes (8) is exceeded, LED DL4 flashes rapidly without memorising
the code.
CANCELLING CODES FROM RADIO CONTROL DEVICES
1_ keep button P-RX pressed for 3 seconds in order to cancel all the associated radio control devices;
2_ LED DL4 flashes slowly to indicate that the cancellation mode has been activated;
3_ press button P-RX again for 3 seconds;
4_ LED DL4 turns off for approx. 3 seconds and then remains steady to indicate that the code has been cancelled;
5_ to exit the learning mode without cancelling a code, press button P-RX briefly.
WARNING: If you wish to memorize a new type of remote control (e.g.: from dip-switches to rolling code
or vice-versa) it is necessary to carry out a delete procedure.
after opening, the overhead door automatically closes when the delay set on
the T.C.A. trimmer expires.
automatic closing disabled.
with automatic closing enabled, a sequence of open/close commands causes
the overhead door to OPENCLOSE-OPEN-CLOSE etc.
in the same conditions, the same command sequence causes the overhead
door to OPEN-STOP-CLOSESTOP-OPEN-STOP (step-by-step).
preflashing enabled, each time the gate is operated the light starts flashing 3
seconds before the gate begins to move.
when the gate is started, it will move immediately.
during opening the overhead door ignores any closing commands.
the overhead door's behavior depends on the position of dip switch No.2. The
direction can be reversed also during the opening manoeuvre.
resistive sensitive edge connected. Connect the resistive sensitive edge, with
the related 8,2 KΩ resistance, to terminals 11-12.
sensitive edge (fixed edge) connected. Connect the fixed edge to terminals 11-
12. If no sensitive edge is used, short circuit terminals 11-12.
the memorization function is enabled for self-learning of the travel.
leave the dip-switch in this position when the memorization procedure has
been completed.