Flotec FPSC3350A Notice D'utilisation page 3

Masquer les pouces Voir aussi pour FPSC3350A:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Installation
12. This equipment is only for use on 115 volt
(single phase) and is equipped with an
approved 3-conductor cord and 3-prong,
grounding-type plug.
Electrical Shock Hazard. Can burn
or kill. To reduce risk of electric shock, pull plug
before servicing. This pump has not been
investigated for use in swimming pool areas.
Pump is supplied with a grounding conductor
and grounding-type attachment plug. Be sure it is
connected only to a properly grounded
grounding-type receptacle.
Where a 2-prong wall receptacle is encountered,
it must be replaced with properly grounded
3-prong receptacle installed in accordance with
codes and ordinances that apply.
13. All wiring should be performed by a qualified
electrician.
14. Make certain power source conforms to
requirements of your equipment.
15. Protect electrical cord from sharp objects, hot
surfaces, oil, and chemicals. Avoid kinking
cord. Replace or repair damaged or worn cords
immediately.
16. Do not touch an operating motor. Motors can
operate at high temperatures.
17. Do not handle pump or pump motor with wet
hands or when standing on wet or damp surface,
or in water.
Hazardous voltage can shock, burn
or kill. If your basement has water or moisture
on floor, do not walk on wet area until all power
has been turned off. If shut-off box is in
basement, call electric company or hydro
authority to shut-off service to house, or call
your local fire department for instructions.
Remove pump and repair or re place. Failure to
follow this warning can result in fatal electrical
shock.
Do not lift pump by power cord.
For parts or assistance, call Flotec Customer Service at
INSTALLATION
1. Install pump in sump pit with minimum diameter
of 11" (28 cm). Sump depth should be 15"
(39 cm). Construct sump pit of tile, concrete,
steel or plastic. Check local codes for approved
materials and for proper installation.
2. Install pump in pit so that switch operating
mechanism has maximum possible clearance.
Adjust the float stop on the rod to adjust the
pump "ON" point. "OFF" point is factory preset.
3. Pump should not be installed on clay, earth or
sand surfaces. Clean sump pit of small stones
and gravel which could clog pump. Keep pump
inlet screen clear.
NOTICE Do not use ordinary pipe joint
compound on plastic pipe. Pipe joint compound
can attack plastics.
4. Install discharge plumbing. Use rigid plastic pipe
and wrap threads with
into pump hand tight plus 1-1/2 turns.
Risk of flooding. If a flexible
discharge hose is used, make sure pump is
secured in sump to prevent movement. Failure to
secure pump may allow pump movement, switch
interference and prevent pump from starting or
stopping.
5. To reduce motor noise and vibrations, a short
length of rubber hose (1-7/8" (47.6mm) I. D.,
e.g. radiator hose) can be connected into
discharge line near pump using suitable clamps.
6. Install an in-line check valve (part number
FP0026-10-P2) to prevent flow backwards
through pump when pump shuts off. If using the
pump in anything other than a sump application,
ensure in-line check valve is installed horizontally.
1
E.I. DuPont De Nemours and Company Corporation, Delaware.
1-800-365-6832
1
Teflon
tape. Screw pipe
3

Publicité

Table des Matières
loading

Table des Matières