Recommended min. cross section and max. cord lengths for tools with a 15 m (50 ft) supply cord:
Conductor cross section
Mains voltage 110-120 V
en
2.9 Using extension cords outdoors
When working outdoors, use only extension cords that are approved and correspondingly marked for this application.
2.10 Using a generator or transformer
This power tool may be powered by a generator or transformer which fulfills the following conditions: The unit must
provide a power output in watts of at least twice the value printed on the type identification plate on the power tool.
The operating voltage must remain within +5% and -15% of the rated voltage at all times, frequency must be in the 50
– 60 Hz range and never above 65 Hz, and the unit must be equipped with automatic voltage regulation and starting
boost.
Never operate other power tools or appliances from the generator or transformer at the same time. Switching other
power tools or appliances on and off may cause undervoltage and / or overvoltage peaks, resulting in damage to the
power tool.
3 Insert tools, accessories
Designation
Depth gauge
Depth gauge
Bit holder
Bit holder
Magazine
Extension
Belt hook
Designation
Bit
4 Technical data
Right of technical changes reserved.
NOTE
The power tool is available in various voltage ratings. Please refer to the type identification plate for details of the
power tool's voltage and power rating.
Power tool
Rated voltage
Mains frequency
Weight
Dimensions (L x W x H)
Rated speed under no load
Max. torque
Chuck
4
16 AWG
50 ft
Description
S‑DG‑D 11 x 50 for 50 mm (2") bit holder
S‑DG‑D 11 x 75 for 75 mm (3") bit holder
S‑BH 50M
S‑BH 75M
SMD 50
SME extension for working on ceilings
Description
S‑B PH2
SD 4500
Rated voltage 120 V: 6.5 A
60 Hz
1.4 kg (3.09 lb)
265 mm (10.43") x 77 mm (3.03") x
170 mm (6.69")
0...4,500/min
9.5 Nm (7 lb/ft)
Hex. socket ¹⁄₄"
DIN 3126 / ISO 1173
14 AWG
75 ft
SD 2500
Rated voltage 120 V: 6.5 A
60 Hz
1.5 kg (3.31 lb)
310 mm (12.2") x 77 mm (3.03") x
170 mm (6.69")
0...2,500/min
19 Nm (14 lb/ft)
Hex. socket ¹⁄₄"
DIN 3126 / ISO 1173
12 AWG
100 ft