indicates that the new stetting has been correctly saved.
pipes, etc.) or too low for the equipment in your installation. If in doubt consult a professional to ensure the pump is
correctly set.
In certain cases it may be necessary to adjust the priming time to allow the air in the hydraulic pipes to be evacuated.
This priming time will be applied each time the pump is started.
To modify the priming time:
The setting is adjusted second by second within the range 0-240 seconds
Once the time setting has been changed, the pump will start by default at 3,000rpm for the duration of the new priming
time.
When the pump is operating in priming mode, a digital bar turns in a circle on the left of the display.
Note: The priming function can be interrupted at any time by a short press on the On/Off button.
To restore the factory settings and erase all the settings, proceed as follows:
The factory settings have been successfully restored.
The default settings are:
1. Completely disconnect the pump from the mains power supply before opening the cover and cleaning the strainer. Clean
the strainer basket regularly. Do not bang on the basket to clean it. Check the seal on the cover of the strainer and
replace it if necessary.
2. The motor shaft is mounted on self-lubricating bearings which do not require any subsequent lubrication.
3. Keep the motor clean and dry and ensure the ventilation openings are not blocked.
4. The mechanical shutter occasionally starts to leak and must then be changed.
5. Apart from cleaning the pool, all repairs, servicing and maintenance must be carried out by a Hayward-approved agent
or a qualified person.
1. Empty the pump by removing all the drain plugs and store them in the strainer basket.
2. Disconnect the pump, remove the pipe connectors and store the entire unit in a dry, well-ventilated place or at least take
the following precaution: disconnect the pump, remove the 4 bolts attaching the pump housing to the motor bracket and
store the unit in a dry, well-ventilated place. Then cover the pump housing and strainer to protect them.
: Before recommissioning the pump, clean all the internal parts to remove dust, lime scale etc.
Page 7 of 8
MAINTENANCE
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
WINTERING
Pump
Rev. C