Information for power adaptor
Power supply adaptor
- Manufacturer: Blue Iron
- Model number: BI12T-120100-I
- Adaptor type: External AC adaptor
- Use only the power supply listed in the user instructions
Assembly
Drive belt:
The belt and turntable platter have been installed properly at factory, but the belt may be loose
during transportation. If so, the following procedures will be taken for belt installation by yourself.
A. Remove the rubber mat from the turntable platter and the E ring from the turntable shaft,
then release the turntable platter from the shaft
B. Put the drive belt on the inner rim of the turntable platter and pull it through the hole
C. Hold the belt with your fingers and place the belt onto the motor pulley as shown in the drawing.
D. Clip the E ring on the shaft and place the rubber mat onto the turntable platter.
Caution:
1. Make sure that the drive belt is not twisted or distorted.
2. Avoid oil. Oil splashes will make the belt slippery.
Auto Return Reset:
Always do the reset for Auto Return once you move this product. The mechanism of Auto Return
will rotate irregularly when moving and it will cause the malfunction of Auto Return. The following
steps will reset the mechanism to normal.
1. Place a record on the platter and play it.
2. Manually lever the tone arm and place it to the blank part of the end of the record.
3. The mechanism of Auto Return function will be adjusted properly and the tone arm will
automatically return to the arm rest.