Before clearing, turn off the power and unplug the appliance from the electrical outlet.
Lift off the tank of the humidifier from the housing.
Carry the water tank and the housing to a sink, drain all the remaining water.
Drain and rinse water tank and housing to remove any sediment and dirt.
Wipe clean and dry with clean soft cloth or paper towel.
Refill the water tank with cool tap water as instructed in filling water tank paragraph.
It is necessary to remove daily any residual water, from both the tank and the tank
and the bowl, then clean and dry both and finally refill with new and clean tap water.
Always unplug the unit before servicing in any way.
• Inside the bowl. Pour excess water out of the unit. Wash the unit with fresh water,
using a soft paintbrush and a soft cloth as necessary.
Do not submerse the base of the unit into water, or allow water to enter inside
the dry air exhaust port of the unit.
• Water tank. Empty water tank. Remove mist nozzle and clean the mist tube with fresh
water and a light brush (a soft paintbrush is advised).
• Outer surface of the unit. Wipe the surface of the unit with a soft, damp cloth if need-
ed. If you notice an accumulation of water during usage, reduce humidity and dry outer
surface with a cloth.
• Ultrasonic Transducer. If you use the hard water, distilled or tap water, you should
clean the transducer weekly.
• Air filter. Remove the grid, clean the filter. Reinstall grid and filter.