Changing The Mains Fuse - Snap-on Equipment JohnBean B600P Manuel D'utilisation

Équilibreuse de roue
Table des Matières

Publicité

1
110
2
6-8
Maintenance
6.4
Storage
When the unit will be stored for a few weeks or longer,
prepare the unit correctly:
• Shut down the unit properly,
• Remove the stub shaft from the balancer.
• Apply a thin layer of non-corrosive oil on all threads
and cones.
• Wrap oiled items in paper to protect parts against
dust.
Before putting the unit into use again, clean all oiled
parts.
6.5

Changing the mains fuse

Refer to Figure 6-8.
• Switch off the unit.
• Unplug the power cable from the power outlet.
• Remove the power cable from the unit connector
(1, Fig. 6-8).
• Pull out the fuse holder (2, Fig. 6-8).
• Replace the damaged fuse with another fuse having
an identical rating.
• Return the unit to its original functioning condition,
by following the steps above in reverse order.
F
5.2.4.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Johnbean b600

Table des Matières