Télécharger Imprimer la page

Rollotec; Specifications - Berker RolloTec Mode D'emploi

Insert
Masquer les pouces Voir aussi pour RolloTec:

Publicité

Les langues disponibles

Les langues disponibles

Connection of RolloTec
breakers (FI).
To avoid undesired tripping of the FI circuit breakers the two 'circuits' must not be
direct-coupled.
Use seperating relay.
36
®
in installations using separate fault-current circuit

5. Specifications

Rated voltage
: 230 V AC, 50 Hz, neutral conductor required
Switching capacity
: one 1000 W motor max.
Relay output
: 2 potential-carrying n. o. contacts (interlocked)
Pulse duration

RolloTec

®
pushbutton
: 2 minutes
RolloTec
®
memory pushbutton
: 2 minutes
RolloTec
®
radio control pushbutton
: 2 minutes
®
RolloTec
clock timer attachment
: 2 minutes standard,
1 second - 12 minutes learned
Switch-over time for cont. running
: 1 second min.
(electronic locking by attachment)
Connecting terminals
: screw-type
for 2.5 mm² max. or 2 x 1.5 mm²
1, 2, N,
,
Automatic cut-out
: 16 A max.
, L
37

Publicité

loading

Produits Connexes pour Berker RolloTec

Ce manuel est également adapté pour:

2975