2. Warning
Attention: Electrical equipment must be installed and fitted by qualified
electricians only.
If different phases are used all poles will have to be disconnected in case of
malfunctioning or when work is done on the installation.
Do not lay control wiring in parallel with motor connection wiring (hazard of coupling).
The RolloTec
Do not switch any other loads.
If louver motors are to be connected in parallel it will be mandatory to observe the
information given by the motor manufacturers. Otherwise, the motors might get
damaged.
Use louvers or roller blinds with limit switches (mechanical or electronic) only.
Please observe the information of the motor manufacturers.
Please observe the information of the motor manufacturers with respect to change-
over time and max. cyclic duration factor.
The RolloTec
louvers. Other applications such as controlling a rolling door may entail danger.
Such danger must be made impossible by the user by employing additional suitable
safety measures (e. g. light barriers).
26
®
system has been designed for switching louver or roller blind motors.
®
system has been designed for the automatic actuation of window
3. Installation Instructions
A
A
Important: The sensor wiring carries protective low voltage (SELV). Please
observe the installation procedures as specified by VDE 0100.
Connecting the Sensor:
Buried Installation (Fig. A):
Choose wiring suitable for buried installation.
Recommendation: J-Y(ST)Y 2x2x0.6 mm² telephone cable. The individual wires of
the sensor wiring should be run through insulating tubing (comes with the inserts
with sensor evaluation). Then, thread the wiring through hole
together with the insulating tubing and lead it to connecting terminal
B
B
duct
. The insulating tubing must cover the individual wires from the outer cable
insulation to the connecting terminal. Place the connecting terminal (comes with the
inserts with sensor evaluation) into the insert as shown in the illustration.
Surface Installation (Push-Button with Sensor Evaluation) (Fig. B):
Thread sensor wiring
the wall and the supporting plate) into line duct
routed directly through the line duct to connecting terminal
precisely located in the line duct and must not form any loops towards the 230 V
connecting terminal chamber.
of the insert
through line
through opening
behind the supporting plate (between
of the insert. The wiring should be
. The wiring must be