b) Cleaning the shaft
• Clean the shaft (4) manually with warm water and some detergent and dry it.
The shaft and the entire device is not suitable for cleaning in a dishwasher.
c) Cleaning of the motor unit
• Only clean the motor unit (3) with a slightly moistened soft cloth.
• Never use any aggressive cleaning agents or chemical solutions for this, as these may damage the
surface of the casing.
• After cleaning, apply the blade protection (5) to the blade again to avoid injury.

14. Disposal

Electronic devices are recyclable waste and must not be disposed of in the household waste!
Dispose of the product according to the applicable statutory provisions at the end of its service
life.

15. Technical data

Operating voltage ........................................220-240 V/50/60 Hz
Power intake .................................................600 W
Max. operating duration .............................30 seconds per work cycle/max. 5 work cycles
Cooling term ..................................................2 minutes after each work cycle
Operating noise (at 1m distance) ..............max. 80 dB(A)
Dimensions (ø x L) ........................................55 x 392 mm
Weight ............................................................787 g