● TESTING CONTINUITY BY USING TONE (SWITCH TO "FAST TONE"
or "SLOW TONE") ●●●
CAUTION:DO NOT CONNECT TO ANY ACTIVE AC OR DC CIRCUIT
IN THIS MODE.
1.●Connect●the●test●leads●to●the●subject●pair.
2.●Use●a●handset●or●headset●at●the●remote●end●and●touch●the●wire●end(s)●●
● with●the●clip●lead(s).
3.●Reception●of●tone●is●an●indication●of●continuity.
● MODULAR TESTING●
1.●All●above●tests●are●available●through●the●modular●plug●for●line●1●only●-●●
● red●and●green●wires.
● COAX TESTING
1.●To●test●unterminated●coax,●connect●red●to●outer●shield●and●black●to●● ●
● center●conductor●or●red●to●outer●shield●and●black●to●ground.
2.●To●test●terminated●coax,●connect●red●to●connector●housing●and●black● ●
● to●center●pin●or●red●to●connector●housing●and●black●to●ground.
-11-