Plug and socket system 63A, GHG 524
In the open air, the plugs must be kept with
the plug opening (pin side) pointing
downwards or be closed with protective plug
caps available as an optional extra (see
general catalogue).
Item 3
6

Installation

For the mounting and operation, the
respective national regulations (e. g. ElexV,
equipment safety law for Germany) as well as
L3
the general rules of engineering will have to be
observed.
6.1

Mounting

The wall sockets can be mounted without
opening their enclosure.
In case the wall sockets are mounted directly
onto the wall, they may rest evenly only at the
respective fastening points. The chosen screw
shall match the fastening hole (see dimensio-
Item 1
nal drawing) and it must not damage the hole
(e. g. use of a washer). The device shall be
fastened diagonally with at least 2 screws.
The wall sockets and flange sockets shall be
Item 3
mounted so that the plug hole does not point
upwards.
Item 1
6.2
Opening the device/
Electrical connection
The electrical connection of the device may
only be carried out by skilled staff.
The insulation of the conductors shall
reach up to the terminal. The conductor
itself shall not be damaged.
Taking into account the respective regulations,
the properly bared conductors of the cables
Item 4
shall be connected.
The electrical connection of the plugs is
established as shown in fig. 4 and 5:
The plug insert (item 2, fig. 5) is removed from
the pin bushing (item 1, fig. 5), after the
fastening screws (item 3, fig. 4) have been
unscrewed. Thereafter, the plug insert can be
connected to the connections of the plug pins
(see view 1, fig. 5).
Attention: When the fastening screws (item
3, fig. 4) get lost, they will have to be
replaced by similar screws or to be ordered
directly from the manufacturer.
Assembly is made in inverse order, after the
cable has been connected.
The inlets are electrically connected as
shown in fig. 6 thru 8.
Fig. 6: After unscrewing the two screws item
3, the plug insert item 2 is removed from the
flange item 2.
Fig. 7: Now the connecting leads item 4 can
be connected to the terminal L1... and PE als
of the plug insert item 2 as described in point
6.2.
Fig. 8: Finally, using the self-cutting screws
item 3, the plug insert item 2 is screwed into
the flange, observing its proper position.
The connectible min. and max. conductor
cross-sections shall be observed (see
technical data).
All screws and/or nuts of the supply
terminals, also of those remaining vacant,
shall be tightened down.
The supply terminals are designed for the
connection of copper conductors. If multi- or
fine-wire connecting cables are used, the wire
ends will have to be handled in acc. with the
applicable national and international rules (e.g.
use of sleeves for strands).
6.3
Cable entries (KLE);
blanking plugs
6.3.1
Plug and socket
Flexible cables shall be used with trumpet-
shaped cable glands or other suitable
entries with additional pull-relief.
When using cable entries with a lower IP
protection than that which applies to the
device (see page 7, technical data), the IP
protection of the whole device will be reduced.
The mounting directives applicable to the
cable entries used shall be observed.
Unused holes shall be closed with a blanking
plug in order to establish the minimum
protection category.
In case of sealing inserts that are cut out, it
shall be ensured that the insert is properly
adapted to the cable diameter. Care has to be
taken that when fitting the cable entries,
sealing inserts appropriate to the cable
diameter are used.
In order to ensure the required minimum
protection category, the cable glands are to
be tightened down.
Overtightening might impair the protection
category.