Quick Guide
(Complete manual in
www.novusautomation.com/en/fieldlogger
FieldLogger is an analog and digital variables data logger module. It has 8
universal analog inputs and 8 digital I/Os. It can act as a Modbus RTU network
master and read registers from other slaves in order to log them into memory or
make them available on its other interfaces. Capable of performing
mathematical operations on the input channels, it has fast reading and logging
rates, a large storage memory, accepts SD card and thumb drive and has a full
set of connectivity options.
The full version of FieldLogger operating and installation manual,
available on the product page, presents to the user all the information
necessary for proper use of all features.
UNPACKAGE
When unpacking, besides this Quick Guide, you will also find:
- One FieldLogger module;
- One USB cable.
INITIAL CONFIGURATION AND SOFTWARE INSTALLATION
FieldLogger configuration is executed through the Configurator application.
FieldLogger
Configurator
downloading
FieldLoggerConfigsetup.exe
file
available
www.novusautomation.com/en/fieldlogger.
Before connecting the FieldLogger to the computer USB port, please install
the Configurator application and the USB drivers. In order to make the first
configuration, please follow these steps:
1. Unpack the FieldLogger and USB cable.
2. Install the Configurator application in the computer (USB communication
drivers will be installed as well).
3. Power on the FieldLogger and connect it to the computer through the USB
cable. In case the drivers have not yet been installed and a window pops up
indicating that a new hardware has been found, check in the manual the
right proceeding to install it.
4. Run the Configurator application and read the equipment configuration. If it
succeeds, you are able to configure and use your FieldLogger. On any
error, check the manual and follow the hints and instructions given by the
Configurator application.
FieldLogger is set with the following factory default configuration:
• RS485 Interface enabled as SLAVE: 19200 bps, no parity, 1 stop bit and
Modbus address 1;
• Ethernet Interface disabled;
• Data logging disabled;
• All analog channels disabled;
• All digital channels disabled (all configured as inputs);
• All virtual channels disabled;
• No alarms configured;
• Download via thumb drive disabled;
• HMI access set only for reading.
SPECIFICATIONS
English
)
Analog Inputs
Analog Accuracy
Digital Inputs /
Outputs
Relay Outputs
RS485 Interface
Ethernet Interface
and
running
the
Supported
at
our
website:
Protocols and
Services
Internal Memory
SD Card
Operating
Environment
Enclosure
Dimensions
Power Supply
Protection
Configuration
Software Operation
Environment
8 analog inputs:
• Thermocouple J, K, T, E, N, R, S and B (IEC-584).
• Pt100, Pt1000 (IEC-751), 0-20 mA, 4-20 mA,
0-20 mV, 0-50 mV, 0-60 mV, - 20-20 mV, 0-5 V
and 0-10V.
• Thermocouple J, K, T, E and N: 0.2 % of range
± 1 °C.
• Thermocouple R, S and B: 0.2 % of range ± 3 °C.
• Pt100, Pt1000, 0-20 mA, 4-20 mA, 0-20 mV,
0-50 mV, 0-60 mV, - 20-20 mV, 0-5 V and 0-10 V:
0.15 % of maximum range.
8 digital channels that can be individually configured
as inputs or outputs.
2 Relays SPST-NO/NC, 3 A / 250 Vac
Can be used as a Modbus RTU slave or master (can
read up to 64 slaves).
10/100 Mbps.
TCP/IP, DHCP, HTTP, SMTP, SNMP, Modbus RTU,
Modbus TCP, FTP server and client.
2 MB.
Up to 16 GB.
0 to 50 °C. Relative Humidity (Maximum): 80 % up to
30 °C. For temperatures above 30 ºC, decrease 3 %
per ºC. Installation category II. Pollution degree 2.
Altitude < 2000 m.
ABS + PC
165 x 117 x 70 mm; Weight: 400 g. (no HMI)
• 100 to 240 Vac/dc (50 / 60 Hz)
• 24 Vdc/ac (50 / 60 Hz)
IP20
Software for Windows® XP, Vista and 7.
Menus in Portuguese, Spanish or English.
Table 01
Q U I C K
G U I D E
QG 5000965 V1.0x E