Metabo HPT DH 28PC Mode D'emploi Et Instructions De Securite page 16

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

English
Grease replenishment
CAUTION:
Before replenishing the grease, turn the
power off and pull out the power plug.
(1) Disassemble the crank case cover and
thoroughly wipe off the old grease inside.
(Fig. 24)
Crank cover
(2) Supply 0.9 oz (25g) of metabo HPT
Electric Hammer Grease A (standard
accessory, contained in tube) in the
crank case.
(3) After replacing the grease, reassemble
the crank case cover securely. At this
time, do not damage or lose the oil seal.
NOTE:
The metabo HPT Electric Hammer
Grease A is of the lower viscosity type.
When the supplied grease tube is
consumed,
metabo
HPT
Center.
16
Fig. 24
purchase
from
Autorized
Service
6. Service and repairs
All quality power tools will eventually
require servicing or replacement of parts
because of wear from normal use. To
assure that only authorized replacement
parts will be used, all service and repairs
must be performed by a
metabo HPT Authorized Service
Center, ONLY.
7.
Service parts list
A: Item No.
B: Code No.
C: No. Used
D: Remarks
CAUTION:
Repair, modification and inspection of
metabo HPT Power Tools must be
carried
out
Authorized Service Center. This Parts
List will be helpful if presented with the
tool to the metabo HPT
Service Center when requesting repair
or other maintenance. In the operation
and maintenance of power tools, the
safety regulations and standards
prescribed in each country must be
observed.
MODIFICATIONS:
metabo HPT Power Tools are constantly
being improved
a
incorporate the latest technological
advancements. Accordingly,
parts (i.e. code numbers
design)
may
prior notice.
metabo HPT
by
an
Authorized
and
modified
some
and/or
be
changed without
to

Publicité

Table des Matières