Main input offset
correction
Select sampling time
(resolution). For linear
input only.
+4 to disable filter
(average of the last eight values sampled)
Digital filter
on main input
Digital filter on process
variable display
Decimal point position for
main input scale
(*) not available for TC, RTD, PTC and NTC scales
Minimum limit of main
input scale and analog
output
Maximum limit of main
input scale and analog
output
Select function of
digital input
Raise key function
(active only in
P.V.selection)
Lower key function
(active only in
P.V.selection)
Low limit for the alarms
set point
High limit for the alarms
set point
Custom Linearization of
L n
main input
Step 0
(beginning of scale value)
the n step value corresponds to input:
.......
mV beginning scale + n *
∆
mV = (mV full scale - mV beginning scale) / 32
Step 32
(end of scale value)
-999 ...999
scale points
0
120ms
> 13bit; 8000 divs
1
60ms
> 13bit; 8000 divs
2
30ms
> 12bit; 4000 divs
3
15ms
> 11bit; 2000 divs
0.0 to 20.0 sec
0.0 to 9.9
scale points
dP
Format
0
XXXX
1
XXX.X
2 *
XX.XX
3 *
X.XXX
min...max scale
of input selected in t.P
min...max scale of input
selected in t.P
d. i. - t. u. - t. d.
0
None
1
Zero
2
Hold
3
Flash
4
Max. peak display
5
Min. peak display
6
Delta peak display
7
Peak memory reset
8
Zero + peak memory reset
9
Alarms reset
10
Peak + alarms reset
11
Zero + alarms reset
12
Peak + zero + alarms reset
13
Output status OUT1
14
Output status OUT2
15
Output status OUT3
L.S to H.S
L.S to H.S
• Custom Linearization
Display limits
(-1999 to 9999 for 4 digit display)
∆
mV
Display limits
(-1999 to 9999 for 4 digit display)
• Output parameters
O u
Output settings
Number of outputs
Alarm type 1
(absolute only)
Alarm type 2
Alarm type 3
+8 to disable on power-up until first alarm
+16 to memorize
+32 to filter with F.O. mode (output filter mode)
Output filter
mode
delay for F.O.
Minimum
output pulse
Fault action (in case of
damaged sensor) Er, br,
• Protection
P r
Protection code
+4 to disable In and Ou pages
+8 to disable Cf page
+16 to enable maintenance of reset latch at power-off (for linear inputs only)
+32 base configuration (the following parameters will not be displayed:
In: Ft, Fd, Of, L_L, H_L
Ou: On [forced to no. outputs present], rE)
Step 33
Step 34
Step 35
(*) only for CPU, TC_LIN and tP = TC CUSTOM
14
0 to 3
1. t - 2. t - 3. t
Value
Direct
Absolute
(max.)
Relative to Symmetrical
previous
Inverse
(min.)
0
Direct
Absolute
1
Inverse
Absolute
2
Direct
Relative
3
Inverse
Relative
4
Direct
Absolute
5
Inverse
Absolute
6
Direct
Relative
7
Inverse
Relative
0 not active: calculated status
is sent directly to relay
1 On delay (DON)
2 On delay after it has been
turned off (DBI)
3 Off delay (DOF)
4 Delay for activation
only at power-up (DPO)
+ 8 time base max. 99 min (default = 99 sec)
0 to 99
min or sec
0 to 99
sec
Disabled by setting value 0
Displayed if associated with at
least one output
Value Output 1 Output 2 Output 3
0
OFF
OFF
1
ON
OFF
2
OFF
Eb
3
ON
4
OFF
OFF
5
ON
OFF
6
OFF
7
ON
Value
Displayed
parameters
0
o.1, o.2, o.3
o.1, o.2, o.3
1
o.1, o.2
2
o.1
3
o.1
mV beginning of
scale
mV end of scale
mV at 50°C
Normal
(window)
Normale
Normale
Normale
Normale
Symmetrical
Symmetrical
Symmetrical
Symmetrical
OFF
OFF
ON
OFF
ON
OFF
ON
ON
ON
ON
ON
ON
Modifiable
parameters
o.1, o.2
o.1
none
(*)
(*)
(*)