gefran 40T 72 Manuel D'utilisation page 10

Masquer les pouces Voir aussi pour 40T 72:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 26
1 • INSTALLATION
• Dimensions and cut-out: Panel mounting
76
72
36
54
8
Panel mounting:
Fix the device with the bracket provided before making any electrical connections.
To mount two or more devices side by side, use the cut-out dimensions shown above.
CE MARKING: EMC (electromagnetic compatibility) conformity to EEC Directive
89/336/CEE with reference to the generic Standard EN50082-2 (immunity in industrial
environments) and EN50081-1 (emission in residential environments). BT (low voltage)
conformity to Directive 73/23/CEE as modified by Directive 93/68.
MAINTENANCE: Repairs must be done out only by trained and specialized personnel.
Cut power to the device before accessing internal parts.
Do not clean the case with hydrocarbon-based solvents (Petrol, Trichlorethylene, etc.).
Use of these solvents can reduce the mechanical reliability of the device. Use a cloth
dampened in ethyl alcohol or water to clean the external plastic case.
SERVICE: GEFRAN has a service department. The warranty excludes defects caused
by any use not conforming to these instructions.
40T 72
UNIVERSAL TEMPERATURE and PRESSURE INDICATOR - ALARM UNIT
83
30
69,5
For correct and safe
installation, follow the
instructions and observe
the warnings contained
in this manual.
USER'S MANUAL
SOFTWARE VERSION 1.0x / 2.0x
code 81646 / edition 03 - 07/01
ISO 9001
2 • TECHNICAL SPECIFICATIONS
Display
Keys
Accuracy
Resolution
(function of settable sample time)
Main input
Thermocouples
43
Cold junction error
RTD type (scale configurable within
indicated range, with or without decimal point)
Max. RTD line resistance
PTC type / NTC type
Max. non-linearity error
°C / °F selection
Linear scale ranges
Logic input (option)
Function of logic input
Alarms (set points)
Alarm masking
!
Relay contact
Logic output
Triac output (option)
Fault settings
2-wire Transmitter Power Supply
(option)
Analog retransmission (option)
Power supply (switching)
Faceplate protection
Working / Storage temperatures
Relative humidity
Installation
Weight
EMC conformity has been tested with the following connections
FUNCTION
TC input probe
"PT100" input probe
Power supply cable
Relay output cables
10
GEFRAN spa via Sebina, 74
25050 Provaglio d'Iseo (BS) ITALIA
Tel. 0309888.1 - Fax 0309839063
Internet: http://www.gefran.com
2, 3, 4 digit red LED's, digit height 14mm
3 mechanical keys (Raise, Lower, F)
0.2% f.s. at 25°C ambient temperature, ts=120msec
120msec, >13bit - 8000 points
60msec, >13bit - 8000 points (only for linear inputs)
30msec, >12bit - 4000 points (only for linear inputs)
15msec, >11bit - 2000 points (only for linear inputs)
TC, RTD, PTC, NTC
60mV, 1V, Ri ≥ 500KΩ; 5V,10V, Ri ≥ 20KΩ
20mA, Ri = 50Ω
adjustable digital filter
J, K, R, S, T, B, E, N
(IEC 584-1, CEI EN 60584-1, 60584-2)
L GOST, U, G, D, C
Custom linearization available on request
0,1° / °C
DIN 43760 (PT100), JPT100
20Ω
990Ω, 25°C / 1KΩ, 25°C
See t.P parameter at page 4
Faceplate configurable
-1999 to 9999 (with 4 digit display)
-999 to 999 (with 3 digit display)
-99 to 99 (with 2 digit display)
Configurable decimal point position, possible 32
segment linearization
Ri = 5,6KΩ (24V, 4mA), isolated to 1500V
configurable to reset memory latch, hold,
flash, zero, select max./ min. peak, peak-peak value
Maximum of three configurable alarms:
absolute, deviation, symmetrical deviation.
Adjustable hysteresis
- exclude on power-up
- latch reset from key and/or external contact
- insert delay filter (DON, DBI, DOF, DPO)
- set minimum intervention time
NO (NC) 5A, 250V
power supply: > 18Vac/dc,
Rout = 560Ω (6V/20mA)
20...240Vac ±10%, 2A max.
Snubberless, inductive and resistive load (I
Alarm states can be configured in probe fault
condition
18V ±10%, 50mA
1,2Vdc for potentiometer > 100Ω
4 to 20mA, max. 60Ω load
11...27Vdc, 18...27Vac ±10%, 50/60Hz, 4,5VA (not isolated)
IP65
0 to 50°C / -20 to 70°C
20 to 85%, non-condensing
Panel mounting
110g for the complete version
CABLE
0,8 mm
compensated 5 mt
2
1 mm
2
1 mm
2
1 mm
2
2
t = 128A
2
s)
LENGTH USED
3 mt
1 mt
3,5 mt

Publicité

Table des Matières
loading

Table des Matières