MAINTENANCE AND INSPECTION

Read section titled "SAFETY" (pages 4 – 8).
● Disconnect air hose and remove all nails
from Nailer when:
1) doing maintenance and inspection; and
2) clearing a jam.
1. Clearing a jam
Remove a jammed nail in the following order:
1 DISCONNECT AIR HOSE.
2 Insert a rod into the outlet.
Tap the rod with a hammer.
Hammer
Rod
Outlet
Nose
Push Lever
Nose Cap
MAINTENANCE
WARNING
Disconnect
1
air hose
Nose cap can be removed from the push lever using a
screwdriver or thin rod.
Screwdriver
3 Remove the jammed nail with a slotted screw
driver.
4 In case of frequent jam, contact a Hitachi
authorized service center.
2. Inspecting the magazine
1 DISCONNECT AIR HOSE.
2 Clean the magazine. Remove plastic tips or
wooden tips which may have accumulated in the
magazine. Lubricate it with Hitachi pneumatic tool
lubricant.
<NR83A5 / NR83A5 (S)>
Magazine
English
Push lever
Nose cap
Nail Feeder
Disconnect
1
air hose
23