INSTRUCTIONS FOR INSTALLATION
of the wall duct.
• Drill a Ø160 mm hole at the point where the wall duct is
required.Through flammable material Ø 230 mm.
• Now vertically connect one or more concentric pipes to
the heater outlet. Press well and fit the strip(s) of clip
binding.
• Place the bend on top of this, fit any horizontal concen-
tric pipes required, and make sure the connections are
gastight.
• Connect the wall duct to the bend or the horizontal
pipes and make sure that this connection is also gastight.
Roof duct with concentric pipes
A duct through a roof can open out anywhere on the
roof, with an extension to the ridge if necessary.
Depending on which of the aforementioned options has
been chosen, the roof duct will be supplied with either
adhesive flashing for a flat roof or a universally adjustable
tile for a slanted roof.
• Determine the position of the appliance and the posi-
tion of the chimney.
• Drill a Ø 160 mm hole at the point where the chimney
is required.Through flammable material Ø 230 mm.
• Now vertically connect the concentric pipes to the
heater outlet. Press well and apply the clip binding.
• Determine the length of the pipes required and ensure
that the adhesive flashing or the universal tile fit proper-
ly.
• Saw the outside pipe off at the length required.
• Connect the roof duct to the concentric pipes.
L=1+2+5+(2x1)=10
1
2x45
3
NB: Alternatively, you can fit the concentric pipes before
installing the heater. In that case the connection to the
outlet of the appliance should be made using a length of
pipe that can be shortened later.
Fitting the fire to an existing chimney
The fire can be fitted into an existing chimney providing
that the chimney / flue dimensions are 150 mm or more.
A special flue kit is required, which can be obtained
from Drugasar or a Drugasar agent. Do not use any
other type of flue system for this.
BS 5871 – 1 : 2001
Any chimney previously used for an appliance burning a
fuel other than gas shall be swept thoroughly before
installing any gas appliance.
Appliances shall be connected only to the types and sizes
of flue system as specified.
For any other information about this flue system please
contact Drugasar or Drugasar approved agent.
Baffle
To ensure that the heater works properly, the baffle
should be fitted in such a way that the heater can be
adjusted according to the customer's pipe system.
The baffle is supplied separately and should be fitted into
the heater as illustrated in fig. 7. Once it has been adjust-
2
L=1+1+4+(2x2)=10
(H totaal= 5m)
(H total = 5m)