● For Nozzle Cleaning
Clean the nozzle with a soft brush to
remove any dirt from the screen.
● For Tank Cleaning
Wash tank out with water to keep it clean.
● For Pump Unit Cleaning
If the pump sticks or backflow occurs,
wash pump unit with water while holding
upside down and manually squeeze pump
several times.
● Once a month:
1. Check all tube connections for any signs of leakage.
2. Wipe away any dust on AC adapter [AC type only].
● Twice a year:
1. Check all fixed connections a nd tighten as needed.
If there will be long periods of time where the dispenser will not be used,
remove all soap from dispenser using the following method.
1. Remove soap from tank and wash tank out with water.
2. Fill the tank with water and set up the dispenser as usual.
3. Flush the line with water by activating dispenser until no soap comes out from
spout. Refill water if necessary.
4. Discard any water left in tank and allow tank to dry.
5. Place the tank back into the controller.
6. Disconnect the power supply until us e resumes.

PERIODIC MAINTENANCE

LONG-TERM NON-USE