Correcting The Filling Quantity For Long Service Hoses - Waeco AirConServiceCenter ASC2500G Notice D'utilisation

Poste de service climatisation
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 171
Service tasks
"Vacuum time" indicates how long the vacuum pump was operating in
total.
"Service completed" indicates the amount of service work performed on
the air conditioning service unit.
9.7
Correcting the filling quantity for long service
hoses
I
NOTE
 If longer or shorter service hoses are required for the device, you
need to adjust the filling quantities to the new hose lengths.
 The service hoses for the high and low pressure sides must always
be of the same length, as otherwise the filling quantities will not be
correctly measured.
1. In the basic menu, use the cursor keys  or  to select "Other
selections":
2. Press ENTER to confirm.
3. Use the cursor keys  or  to select "Service":
4. Press ENTER to confirm.
5. Enter the password "7732".
6. Enter the hose length in centimetres.
7. Press ENTER to confirm.
102
Vacuum time
Total
min.
STOP-EXIT
Service completed:
Total
STOP-EXIT
Short selection
Free selection
Other selections
ENTER-OK
Int. vessel filling
Flushing
Reset scales.
Service.
ASC2500G/ASC3500G LE
07/03/18
79
08/03/18
4
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Airconservicecenter asc3500g le

Table des Matières