Troubleshooting - Waeco AirConServiceCenter ASC2500G Notice D'utilisation

Poste de service climatisation
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 171

Troubleshooting

11
Troubleshooting
Problem
The display shows
"Warning!
Internal vessel overpres-
"
sure!
The display shows
"Warning!
"
Internal tank is full!
The display shows
"Warning!
Pressure inside the A/C
system.
"
Recovery start!
The display shows
"Warning!
Pressure inside the A/C
"
system
The display shows
"Not enough vacuum!
"
Carry on?
The display shows
"A/C system leakage!
"
Carry on?
The display shows
"Drained oil glass empty-
"
ing!
The display shows
"Warning!
Not enough vacuum for
"
injection!
The display shows
"Quantity too large.
"
Fill internal vessel!
108
Cause
Normal message that
appears during the recycling
process.
The internal refrigerant con-
tainer is too full to hold the
quantity to be extracted.
Normal message that
appears at the start of the
vacuum process. There is
still pressure present in the
air conditioning system.
Message during the vacuum
process. There is pressure in
the air conditioning system.
Message that appears during
the vacuum process if the
pressure in the air condition-
ing system after 8°minutes is
still more than 50°mbar.
Message at the end of the
vacuum process. The air
conditioning system shows a
vacuum loss of more than
120°mbar during the check-
ing time.
This message appears dur-
ing the extraction or recycling
process if there is more than
150°ml of used oil in the con-
tainer.
Message that appears during
the filling phase if the vac-
uum in the air conditioning
system is insufficient to end
the process.
This message appears dur-
ing the filling process if there
is not enough refrigerant in
the internal container to finish
the process.
ASC2500G/ASC3500G LE
Remedy
To continue, press ENTER
for three seconds.
If this message appears
repeatedly, notify customer
services.
Drain the internal refrigerant
container in the proper man-
ner.
No action is required. The
process continues automati-
cally.
No action is required. The
process continues automati-
cally.
Check the air conditioning
system or the connections
between it and the
AirConServiceCenter for
leaks.
Check the air conditioning
system or the connections
between it and the
AirConServiceCenter for
leaks.
Dispose of the content of the
used oil container in an envi-
ronmentally responsible
manner.
Check the air conditioning
system or the connections
between it and the
AirConServiceCenter for
leaks.
Fill the refrigerant container.
EN

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Airconservicecenter asc3500g le

Table des Matières