Use Of The Control Display; Presentation; Starting Up; Before Starting Up, Check - Zodiac PSA Red Line+ 3 Notice D'installation Et D'utilisation

Réchauffeur electrique
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1

5. USE OF THE CONTROL DISPLAY

5.1 Presentation

The "Bazic" control unit fitted in the front side is equipped with :
-
A digital display of 2 digits (1)to display the current and required pool's temperatures
-
Two sensitive switches to adjust the required temperature (2)
-
A sensitive ON/OFF switch (3)
-
An ON/OFF LED (on : LED Green)(4)
-
An operation state LED (5)
1
2
Comments :
* the adjustment range of the set point varies between 2° and 40°C. This max. temperature may be decreased in order to
protect the swimming pool liner, or it may be increased for specific purposes.
In order to change this max. set point, access the menu parameters and change the parameter "r2" (see procedure below):
- 1 – Turn the regulator switch OFF; the "on" light goes off and the water temperature of the pool is displayed.
- 2 – Press the UP and DOWN (
- 3 – Press the
key to re-enter the number 80, the access code for the menu parameters, using the
- 4 – Press the
key to validate this code;
- 5 – Press the UP and DOWN (
- 6 - Press the UP (
Note: in order to display the parameter value "r2", press the key
- 7 – Press the UP and DOWN (
5.2 Setting of the temperature
The temperature is set by means of the sensitive keys (2)
Display the value of the required temperature by pushing either the downward o upward key.

6. STARTING UP

6.1 Before starting up, check:

The hydraulic fittings are correctly tightened.
There is no leak.
The appliance is stable.
The connections of the electric cables are correctly tightened. Incorrectly tightened cables may cause overheating
of terminals.
The appliance is correctly connected to the ground.
No tools or objects have been forgotten inside the appliance.
The water contained in the appliance is not frozen. In event of frost, the heater shall not operate.
while heating : fix LED
temporisation in process: blinking LED
5
4
3
+
) keys simultaneously for five seconds until
is displayed.
+
) keys simultaneously for five seconds.
) key to view each parameter until
- Important: press the
+
) keys simultaneously to return to the pool water temperature display screen.
Protection fuse (T3,15H250V)
Notice: Neither display nor operation if out of
order
is displayed.
, then to change it, press the
key in order to validate this new setting –
6
is displayed.
or
keys.
or
key.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Psa red line+ 6Psa red line+ 9Psa red line+ 12

Table des Matières