Troubleshooting - M Confort ELITE 8 Manuel De L'utilisateur

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

6. Troubleshooting

No.
Problem
The machine is not working and
1.
buttons do not respond when
pressed.
No air flows from the unuit
2.
while the machine is working.
The pump is working but air is
3.
not cool enough.
The pump fails
4.
The pump functions but does
5.
not circulate water, or the
cooling pads contain too litle
water.
Water spitting from the unit.
6.
Undesirable odor.
7.
White sediments in water tank.
8.
Possible cause
Blackout or faulty power connection.
AC fuse is damaged or the circuit
stops functioning in order to prevent
power overload.
Remote control batteries have run out Change batteries.
Remote control or control panel is
damaged.
Damaged motor.
Incorrect motor connection or loose
motor connection.
Thermal protection inside the motor
is working.
Dust filters are clogged
Cooling pads are clogged.
Cooling pads are dry or contain
insufficient water while the
evaporative air cooler is working.
Excessively high relative humidity.
Damaged pump.
Loose pump motor connection.
Clogged top water distribution tray.
Clogged water supply hose or pump
strainer.
Cooling pad out of position.
Clogged top water distribution tray.
The unit is placed in an area where
undesirable odors are present, or
algae are present in water tank.
Water has high content of salt.
08
Solution
Measure input voltage and
connect to a deignated power
supply.
Replace the fuse or restart the
unit.
Repair/replace motor with
another of the same model.
Repair/replace motor with
another of the same model.
Determine wether or not motor
connections are in order.
Turn off the unit until the fan
motor is cool enogh to work.
Clean/replace dust filters.
Clean/replace cooling pads.
Check the top water distribution
tray to determine wether or not
there is a clog. Determine if the
pump is functioning correctly.
Make sure there are at least
one door and one window
opened.
Clean/replace pump with one
of the same model.
Tighten connection.
Clean top water distribution
tray.
Clean the water hose or remove
the particles clogged at the
pump strainer.
Place cooling pad in the right
position.
Clean top water distribution
tray.
Clean water tank and cooling
pads.
Drain water tank cnd clean
cooling pads more frequently.
Remarks
If preoblem continues, please
contact Technical Service.
Contact Technical Service.
Contact Technical Service.
Contact Technical Service.
When the air cooler is used for
a long period of time, room
relative humidity will be very
high if room's air is not
renewed.
Contact Technical Service.
Contact Technical Service.

Publicité

Table des Matières
loading

Table des Matières