RAIS/attika Q-TEE II Manuel D'utilisateur page 99

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 126
English
Placement of Q-Tee II
Installation distance from a combustible wall
The stove is placed on a non-combustible floor.
Using non insulated 150mm I.D. flue pipe, the minimum distance to combustible wall
must be 450 mm from the flue.
Normal set-up - corner setting
A. Distance to furniture (min.)
Distance to flammable materials (min.)
C. to the side (floor)
D. to the rear (wall)
E. to the side of the wall
If the stove is to be installed on a wooden floor, it must be covered
with a non-combustible material at least 12 mm thick, in accordance
with UK Building Regulations
Approved Document J. The stove is to be elevated min. 100 mm, for
example placed on a non-combustable base.
Distance to flammable materials (min.)
B. in front (floor) Stove elevated 0 mm
B. in front (floor) Stove elevated 100 mm
Without Reflector
E
attika
RAIS/
- User manual for RAIS Q-TEE II / Q-Tee II C
Uninsulated
Insulated
flue
flue
1200 mm
1200 mm
if distances are not shown,
national/local regulations are followed
300 mm
200 mm
400 mm
400 mm
465 mm
465 mm
300 mm
300 mm
With Reflector
Uninsulated flue
with Reflector
1200 mm
200mm
400mm
465 mm
300 mm
19